Basic Info.
Model NO.
BSC-1100IIB2-X
Certification
CE, ISO9001, ISO13485
Usage
Research Institute, Hospital, School, Company, Industry
Noise
No More Than 67dB
Type
Biological Safety Cabinet
Product Name
Class II B2 Biological Safety Cabinet
Model
Bsc-1100iib2-X
External Size (W*D*H)
1100*775*2250mm
Internal Size (W*D*H)
940*600*660mm
Tested Opening
Safety Height 200 mm(8′′)
Max Opening
480mm(15′′)
ULPA Filter
2, 99.995% Efficiency at 0.3um. Filter Life Indi
Front Window
Motorized. Toughened Glass . Anti UV
Package Size
1540*1080*1900mm
Gross Weight
340kg
Display
LCD Display
Control System
Microprocessor
Airflow System
70% Air Recirculation,30% Air Exhaust
Work Surface Height
770mm(Can Be Customized)
Caster
Footmaster Caster
Transport Package
Caron Box
Specification
Package Size(W*D*H): 820*910*1500mm
Trademark
BIOBASE
Origin
China
Production Capacity
1000
Product Description

Three protection: operator, sample and environment. Airflow system: 70 % air recirculation, 30% air exhaust A2 Cabinet is suitable for working with microbilogical research in the absence of working with microbiological research in the absence of volatile or toxic chemicals and radionuclide.

1. Color key display: large screen, more clear and dynamic display of various values of the safety cabinet, and has the function of appoinment timing.2.Automatically adjust the wind speed.3. With power-off memory function, the state before power-of wil be restored after power-on, and there wil be visual prompts and alarms4. The integrated design of the operation area makes it easy to disassemble and clean.5. The cabinet is separated from the base. The height of the adjustable base can be customized.6. lnterlocking function: UV lamp and front window; UV lamp and fan, LED lamp; fan and front window.7. it has the function of appointment timing, which can automatically set the time of starting and shuting down the safety cabinet and the
running time of ultraviolet lamps, fans and sockets.
8. The front window closes the double trigger signal, so that the steriization and disinfection function of the ultraviolet lamp is normally turned on.
9. The negative pressure air duct is equipped with a foreign mater filtering structure to prevent foreign matter such as paper scraps from entering the fan system and affecting the normal operation of the product.
10.The front window glass has a one-key lift function
11. The cabinet is designed with a 10* inclination angle, which is in line with ergonomic principles, with a larger viewing angle, convenient operation and more humanization.
12. The one-piece hand rest has a large flat surface, which has a larger contact area with the arm and is more comfortable.
running time of ultraviolet lamps, fans and sockets.
8. The front window closes the double trigger signal, so that the steriization and disinfection function of the ultraviolet lamp is normally turned on.
9. The negative pressure air duct is equipped with a foreign mater filtering structure to prevent foreign matter such as paper scraps from entering the fan system and affecting the normal operation of the product.
10.The front window glass has a one-key lift function
11. The cabinet is designed with a 10* inclination angle, which is in line with ergonomic principles, with a larger viewing angle, convenient operation and more humanization.
12. The one-piece hand rest has a large flat surface, which has a larger contact area with the arm and is more comfortable.
Model | BSC-1100IIB2-X | BSC-1300IIB2-X | BSC-1500IIB2-X | BSC-1800IIB2-X | |
External Size(W*D*H) | 1100*775*2250mm | 1300*775*2250mm | 1500*775*2250mm | 1800*775*2250mm | |
Internal Size(W*D*H) | 940*600*660mm | 1150*600*660mm | 1350*600*660mm | 1625*600*660mm | |
Tested Opening | Safety height 200mm(8") | ||||
Max Opening | 480mm | ||||
Inflow Velocity | 0.53±0.025m/s | ||||
Downflow Velocity | 0.33±0.025m/s | ||||
ULPA Filter | Two, 99.9995% efficiency at 0.12μm, filter life indicator | ||||
Front Window | Motorized. Two-layer laminated toughened glass≥6mm. Anti UV | ||||
Noise | ≤65dB | ||||
UV Lamp | 30W*1 | 30W*1 | 40W*1 | 40W*1 | |
UV timer, UV life indicator, emission of 235.7 nanometers for most efficient decontamination | |||||
LED Lamp | 12W*2 | 14W*2 | 16W*2 | 16W*2 | |
Illumination | ≥1000Lux | ||||
Consumption | 1300W | 1300W | 1300W | 1300W | |
Waterproof Socket | Two, total load of two sockets: 500W | ||||
Display | LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and downflow velocity, filter life, humidity and temperature, system working time etc. | ||||
Control System | Microprocessor | ||||
Airflow System | 0% air recirculation, 100% air exhaust | ||||
Visual and Audio Alarm | Abnormal airflow velocity, Filter replacement, Front window at unsafe height, High filter pressure alarm, abnormal power failure | ||||
Material | Work Zone: 304 stainless steel | ||||
Main Body: Cold-rolled steel with anti-bacteria powder coating | |||||
Work Surface Height | 770mm(can be customized) | 800mm(Can be customized) | |||
Caster | Footmaster caster | ||||
Power Supply | AC220V, 50/60Hz; 110V, 60Hz | ||||
Standard Accessory | LED lamp 2pcs, UV lamp 2pcs, Base stand, Remote control, Foot switch, Drain valve, Waterproof socket 2pcs, Exhaust blower, Exhaust duct | ||||
Optional Accessory | Water and gas tap, Electric height adjustable base stand, Armrest | ||||
Gross Weight | 243kg; 52kg | 282kg; 64kg | 300kg; 64kg | 408kg; 64kg | |
Package | Main Body Exhaust Blower(W*D*H) | 1230*990*1840mm | 1430*990*1840mm | 1630*990*1840mm | 1930*990*1840mm |
930*800*700mm | 930*860*740mm | 930*860*740mm | 930*860*740mm |